H07Z1-K 1 x 6mm2 (450/750V)
Lägg till en bevakning så meddelar vi dig så snart varan är i lager igen.
H07Z1-K 1 x 6mm2 (450/750V)
Kabeln är främst avsedd att användas för fast skyddad installation av signal- och reglerkretsar i apparater.
Se teknisk information nedan och i bifogat produktblad.
Förpackning: Ring, 100 meter
TEKNISK INFORMATION
Nominal cross-section area: 1 x 6mm2
Insultation thickness: 0,8mm
Overall diameter: 4,7mm
Maximum Electrical resistance at 20ºC): 3,30
Standards
Construction & tests: EN 50525-3-31, UNE 211002.
Low voltage Directive: 2014/35/UE.
CPR Regulation (EU) nº 305/2011:
Reaction to fire: B2ca-s1a,d1,a1.
AENOR certification.
RoHS compliant.
CABLE DESCRIPTION
Based on the European standard EN 50525-3-31 & Spanish standard UNE 211002.
Technical designation: H07Z1-K (AS) TYPE 2
Rated voltage: 450 / 750 V A.C. (Uo/U)
Maximum admissible voltages (EN 50565-1):
Alternating current (A.C.)
Phase conductor and earth: 480
Two phase conductors: 825
Direct current (D.C.)
Phase conductor and earth: 620
Two phase conductors: 1.240
Maximum conductor temperature
Normal Operation: 70 ºC
Short circuit (t≤5 s): 160 ºC
Voltage test
2,5 kV A.C
Reaction to fire.
Standards
Declared performances: B2ca-s1a, d1, a1 EN 50575:2014+A1:2016.
Flame retardant: EN 60332-1-2; IEC 60332-1 (H≤425 mm).
Fire retardant: EN 50399 (20,5 kW) (Fs ≤ 1,5 m).
Heat generation & FIGRA: EN 50399 (20,5 kW): THR ≤ 15 MJ; Peak HRR ≤ 30 kW; FIGRA ≤ 150 W/s.
Low production and opacity of emitted smokes: s1 (EN 50399): TSP ≤ 50 m2 and Peak SPR ≤ 0,25 m2/s. s1a: “s1” & transmittance ≥ 80 % (UNE-EN 61034-2; IEC 61034-2).
Flaming droplets and/or particles: EN 50399 (20,5 kW) (If no flaming droplets/particles persisting longer than 10 s occurs)
Low acidity and conductivity of the emitted gases:EN 60754-2; IEC 60754-2. (a1: pH > 4,3; Conductivity < 2,5 μS/mm)
System AVCP: 1+.
Notified body: 0099 (AENOR S.A.U.).
DoP: MB2H07Z1KTYPE2
Range:1,5 / 2, 5 / 4 / 6 / 10 / 16 / 25 / 35 / 50 / 70 / 95 / 120 / 150 / 185 / 240 mm2
Other fire performances (where CPR Regulation is not applicable):
- Fire retardant: EN 60332-3-24 / IEC 60332-3-24 (Cat. C).
- Halogen free: EN 60754-1 / IEC 60754-1 (HCl < 0,5 %; Fluor < 0,1 %)
Conductor
Flexible, annealed copper conductor, class 5 acc. to the International & Spanish standard IEC 60228; UNE-EN 60228.
Insulation
Halogen free, thermoplastic polyolefin insulation, Type TI 7 acc. to the European standard EN 50363-7.
Temperature ranges:
‐ Maximum storage temperature: +40 ºC.
‐ Maximum installation and handling temperature: +5 ºC.
‐ Minimum temperature: -15°C (permanently installed without mechanical exigencies, vibrations and movements)
‐ Minimum bending radii (in mm) at cable temperature of 20 ºC +/- 10 ºC:
- 4xD (D ≤ 8 mm); 5xD (8 mm < D ≤ 12 mm); 6xD (D > 12 mm);
- D= Overall diameter of the insulated conductor in mm.
The tension applied to a cable shall not exceed the following values of tensile stress per conductor, subject to a
total maximum tensile force of 1.000 N. 50 N/ mm2 (during installation)
In circumstances where a stress exceeding these values would result, a separate stress-bearing member or
device shall be used. The method of attaching such a member or device to the cable shall be such that the cable is not damaged.